A control panel operation process:
1 dials on the total power switch.
2 press start button on the controller, a green light emitting diode and light.
3open the high pressure, gas, oil mist purifying button switch.
4two groups of high knob to the right up to the maximum.
The 5strip tension after the pneumatic door switch is closed, then the roller wheel is the strip surface drag along, thus beginning. ( high pressure, gas, oil mist purifying signal lights, high pressure pointer table place right )
6pump knob switch to automatically position should. ( automatic: short float level switch to control the oil level in the tank; Manual : when the upper oil tank level low alarm, automatic oil or liquid level switch fault, then the pump switch to manually turn the oil pump to the fuel tank, visual on the oil in the tank is almost full when the oil pump switch button to automatically.
7 under the low oil level alarm lights emergency gas in the tank, the visual look oil over level gauge can stop refueling.
Two . XCTZ-2controller operation:
1press key (shows the input password ), loses the password and then press set key to enter the menu, press the +, -, exit, the setting key, to adjust the system parameters for each phase. (for details, please read the manual )
The 2set of system parameters:
1) the belt speed cap called100-1000M / min
2) the belt speed limit of0005 M / min
3) the temperature upper limit:0360 C
4) the temperature limit:0320 C
5) the maximum amount of oil:0340ml / min
6) working mode:0000 for gear speed ( automatic control fuel injection). 0002 for the constant oil output ( for the manual injection ).
7) gear coefficient: adjusting the parameters of the system can be and leveling machine belt speed consistency.
8) speed voltage: unused.
9) temperature calibration:0012
10) change password: user can modify this code, but after the change in mind.
11) start oil quantity:0020
12) oil limited:350ml / min
13) choice of language:0000Chinese,0001 for english.
14) pump speed calibration:108
3following the presentation controller two (mode ):
1) gear speed:0000( set of 4zero for gear speed, automatic control for injection. Encoder speed to control the operation of machine work, when the encoder stops rotating oil will stop coated )
This kind of mode fifth) maximum fuel system parameter settings in 340ml / min.
2) a constant output:0002( setting the mantissa is 2for constant output, for manual control of fuel injection).
The change of system parameters ( maximum fifth ) oil ) to set the gear pump oil output. (0030mL-0340mL / min )
The selected constant output mode when the encoder to rotate it and it doesn't matter, no display speed, nor with the speed of injection, shows the oil quantity is a constant quantity, when stopped only by the controller on the reset button to stop. Adjustment only when20ml / min add to. ( a maximum of 0340 mL / min )
Note: the constant output mode is used to switch gear gun must be the biggest oil to add0340 mL / min.
Three. The oiler fuel quantity control parameter setting:
The controller ( first ) with a speed limit) parameter setting more hours out of the oil amount is larger, parameter setting more oil output is smaller; it is because the gear pump oil quantity per minute maximum 340ml, if the belt speed limit set in the 300M / min if you divide 340 by300to1.1ml the oil quantity is big; such as belt speed limit set in the 600M / min is340 divided by6000.5ml oil amount is small, can be according to their own requirements to set the oil belt upper value parameter, parameter adjustment for as long as50to plus or minus down.
Be careful.
Lower tank level low alarm to emergency refueling.
Oil mist recovery filter wool 15working days for a time, only to replace the bottom of the two filter cotton.